MGE Galaxy 3500 15 kVA 3:1
Part# G35T15K3I4B4S
EAN:0731304278504
MGE Galaxy 3500 3:1 with 4 Battery Modules - UPS - AC 400 V - 12 kW - 15000 VA - 3-phase - RS-232 - output connectors: 3
Native product specifications. The product description originates from Cnet. Foxway Distribution accepts no responsibility for error or misinformation in product descriptions from Cnet.
Product specifications
Product Description | MGE Galaxy 3500 3:1 with 4 Battery Modules - UPS - 12 kW - 15000 VA |
Manufacturer Warranty | 1-year warranty |
Dimensions (WxDxH) | 52.3 cm x 83.8 cm x 149 cm |
Weight | 656 kg |
Networking | RS-232 |
Device Type | UPS - external |
Battery | Lead Acid |
Remote Management Protocol | SNMP, HTTP |
Input Voltage | AC 400 V |
Output Voltage | AC 230 V ± 5% |
Included Accessories | Bolt down brackets |
Input Wiring | 3-phase |
Batteries Qty | 4 |
Power Capacity | 12 kW / 15000 VA |
Input Connectors | 1 x hardwire 5-wire (3PH + N + G) |
Output connectors | 1 x hardwire 4-wire (3PH + G) ¦ 1 x hardwire 5-wire (3PH + N + G) ¦ 1 x Terminal Block (Screw) |
General features
Device Type | UPS - external |
Ports
Interfaces | 1 x management (RS-232) ¦ 1 x EPO (emergency power off) |
Expansion Slots | 1 (total) / 0 (free) x SmartSlot |
Warranty
Service & Support | Limited warranty - 1 year ¦ Installation - availability: 8 hours a day / Monday-Friday ¦ Configuration - availability: 8 hours a day / Monday-Friday |
Network
Remote Management Interface | RS-232 |
Remote Management Protocol | SNMP, HTTP |
Compliance
Included Accessories | Bolt down brackets |
Cables Included | Serial cable - external |
Features | LCD display, audible alarm, emergency power off, LCD display, built-in maintenance bypass, built-in static bypass |
Compliant Standards | ISO 9001, IEC 61000-3-2, IEC 61000-3-3, ISO 14001, EN 50091-2, IEC 62040-3, IEC 62040-1-1 |
Software
Software Included | Drivers & Utilities |
HDD / SSD tolerance
Min Operating Temperature | 0 °C |
Max Operating Temperature | 40 °C |
Humidity Range Operating | 0 - 95% |
Sound Emission | 51.3 dBA |
Battery
Quantity | 4 |
Technology | Lead Acid |
Recharge Time | 5 hours |
Capacity
UPS Technology | On-line |
Input Voltage | AC 400 V |
Input Voltage Range | AC 304 - 477 V |
Input Voltage Range (Adjustable) | AC 340 - 460 V |
Frequency Provided | 47 - 53 Hz |
Input Wiring | 3-phase |
Frequency Required | 40 - 70 Hz |
Input Connectors | 1 x hardwire 5-wire (3PH + N + G) |
Power Output Connectors Details | 1 x hardwire 4-wire (3PH + G) ¦ 1 x hardwire 5-wire (3PH + N + G) ¦ 1 x Terminal Block (Screw) |
Output Voltage | AC 230 V ± 5% - 47 - 53 Hz |
Power Capacity | 12 kW / 15000 VA |
Output Waveform | Sinewave |
Circuit Protection | Circuit breaker |
Physical dimensions
Width | 52.3 cm |
Depth | 83.8 cm |
Height | 149 cm |
Weight | 656 kg |
Shipping dimensions
Shipping Width | 65 cm |
Shipping Depth | 106 cm |
Shipping Height | 164 cm |
Shipping Weight | 687 kg |
Specifications
10-40kVA compact 3 phase UPS power protection with excellent efficiency and optimized footprint particularly adapted for demanding industrial environments.
- Dobbelt netindgang
Øg tilgængeligheden ved at lade UPS"en være tilsluttet to separate strømkilder. - Mulighed for parallel-redundans
Strømforsy det tilsluttede udstyr med flere UPS"er for at øge systemets redundans. - Dobbelt netindgang
Øg tilgængeligheden ved at lade UPS"en være forbundet til to separate strømkilder. - Hot-swappable batterier
Sikrer ren, uafbrudt strøm til beskyttet udstyr, mens batterierne udskiftes. - Mulighed for parallel kapacitet
Øg den samlede strømkapacitet ved at bruge flere UPS"er samtidigt. - Frekvens- og spændingsregulering
Giv højere applikationstilgængelighed ved at korrigere dårlige frekvens- og spændingsforhold uden at bruge batteriet. - Servicering med frontadgang
Forenkler installation og vedligeholdelse, samtidig med at pladskravene minimeres. - Miljøovervågning
Forebyg udstyrssvigt fra en lang række truende miljøforhold. - Hørbare alarmer
Giv besked om ændrede strøm- og UPS-forhold. - Korrektion af indgangseffektfaktor
Minimerer installationsomkostningerne ved at gøre det muligt at bruge mindre generatorer og kabler.